Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Spinal Cord ; 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627568

RESUMEN

DESIGN: Prospective diagnostic study. OBJECTIVES: Anatomical evaluation and graduation of the severity of spinal stenosis is essential in degenerative cervical spine disease. In clinical practice, this is subjectively categorized on cervical MRI lacking an objective and reliable classification. We implemented a fully-automated quantification of spinal canal compromise through 3D T2-weighted MRI segmentation. SETTING: Medical Center - University of Freiburg, Germany. METHODS: Evaluation of 202 participants receiving 3D T2-weighted MRI of the cervical spine. Segments C2/3 to C6/7 were analyzed for spinal cord and cerebrospinal fluid space volume through a fully-automated segmentation based on a trained deep convolutional neural network. Spinal canal narrowing was characterized by relative values, across sever segments as adapted Maximal Canal Compromise (aMCC), and within the index segment as adapted Spinal Cord Occupation Ratio (aSCOR). Additionally, all segments were subjectively categorized by three observers as "no", "relative" or "absolute" stenosis. Computed scores were applied on the subjective categorization. RESULTS: 798 (79.0%) segments were subjectively categorized as "no" stenosis, 85 (8.4%) as "relative" stenosis, and 127 (12.6%) as "absolute" stenosis. The calculated scores revealed significant differences between each category (p ≤ 0.001). Youden's Index analysis of ROC curves revealed optimal cut-offs to distinguish between "no" and "relative" stenosis for aMCC = 1.18 and aSCOR = 36.9%, and between "relative" and "absolute" stenosis for aMCC = 1.54 and aSCOR = 49.3%. CONCLUSION: The presented fully-automated segmentation algorithm provides high diagnostic accuracy and objective classification of cervical spinal stenosis. The calculated cut-offs can be used for convenient radiological quantification of the severity of spinal canal compromise in clinical routine.

2.
Neurol Clin Pract ; 14(2): e200272, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38585435

RESUMEN

Background and Objectives: Spontaneous intracranial hypotension (SIH) caused by a spinal CSF leak is a multisymptom syndrome, which can dramatically affect physical and mental health. However, systematic data on health-related quality of life (HRQoL) and mental health are scarce. We hypothesized that surgical treatment leads to significant and sustained improvements in HRQoL and mental health in patients with SIH. Methods: In this single-center cohort study, we prospectively collected HRQoL and mental health data in patients undergoing surgical closure of a spinal CSF leak from September 2020 to November 2022. EuroQoL (EQ-5D-5L), including the health state index (EQ-Index) and the visual analog scale (EQ-VAS), measured HRQoL. The 21-item version of the Depression Anxiety Stress Scales (DASS-21) measured symptoms of mental health. Follow-ups were performed 3 and 6 months postoperatively. Primary outcome was the change in EQ-Index, EQ-VAS, and DASS-21 subscales. Secondary outcome was the impact of baseline depression symptoms on HRQoL outcomes following surgery. Results: Seventy-four patients were included. EQ-VAS improved from 40 (interquartile range [IQR] 30-60) preoperatively to 70 (IQR 55-85) at 3 months and to 72 (IQR 60-88) at 6 months postoperatively (p < 0.001, respectively). EQ-Index increased from 0.683 (IQR 0.374-0.799) to 0.877 (0.740-0.943) at 3 months and to 0.907 (0.780-0.956) at 6 months postoperatively (p < 0.001, respectively). Depression, anxiety, and stress significantly improved after surgery. Preoperative depressive symptoms did not affect the HRQoL outcome. Discussion: The severe impact of a spinal CSF leak on HRQoL and mental health significantly improved after closure of the leak. Higher levels of depressive symptoms do not predict worse outcomes and should not discourage invasive treatment. Further systematic evaluation of outcomes, with special regard to quality of life, is needed, as it allows a comparison of symptom burden between SIH and more familiar diseases as well as a comparison of different treatment modalities in future studies.

3.
J Clin Med ; 12(15)2023 Aug 04.
Artículo en Inglés | MEDLINE | ID: mdl-37568527

RESUMEN

BACKGROUND: Transforaminal lumbar interbody fusion (TLIF) is one of the most frequently performed spinal fusion techniques, and this minimally invasive (MIS) approach has advantages over the traditional open approach. A drawback is the higher radiation exposure for the surgeon when conventional fluoroscopy (2D-fluoroscopy) is used. While computer-assisted navigation (CAN) reduce the surgeon's radiation exposure, the patient's exposure is higher. When we investigated 2D-fluoroscopically guided and 3D-navigated MIS TLIF in a randomized controlled trial, we detected low radiation doses for both the surgeon and the patient in the 2D-fluoroscopy group. Therefore, we extended the dataset, and herein, we report the radiation-sparing surgical technique of 2D-fluoroscopy-guided MIS TLIF. METHODS: Monosegmental and bisegmental MIS TLIF was performed on 24 patients in adherence to advanced radiation protection principles and a radiation-sparing surgical protocol. Dedicated dosemeters recorded patient and surgeon radiation exposure. For safety assessment, pedicle screw accuracy was graded according to the Gertzbein-Robbins classification. RESULTS: In total, 99 of 102 (97.1%) pedicle screws were correctly positioned (Gertzbein grade A/B). No breach caused neurological symptoms or necessitated revision surgery. The effective radiation dose to the surgeon was 41 ± 12 µSv per segment. Fluoroscopy time was 64 ± 34 s and 75 ± 43 radiographic images per segment were performed. Patient radiation doses at the neck, chest, and umbilical area were 65 ± 40, 123 ± 116, and 823 ± 862 µSv per segment, respectively. CONCLUSIONS: Using a dedicated radiation-sparing free-hand technique, 2D-fluoroscopy-guided MIS TLIF is successfully achievable with low radiation exposure to both the surgeon and the patient. With this technique, the maximum annual radiation exposure to the surgeon will not be exceeded, even with workday use.

4.
Neuroradiology ; 65(10): 1545-1554, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37386202

RESUMEN

PURPOSE: Detection of T2 hyperintensities in suspected degenerative cervical myelopathy (DCM) is done subjectively in clinical practice. To gain objective quantification for dedicated treatment, signal intensity analysis of the spinal cord is purposeful. We investigated fully automated quantification of the T2 signal intensity (T2-SI) of the spinal cord using a high-resolution MRI segmentation. METHODS: Matched-pair analysis of prospective acquired cervical 3D T2-weighted sequences of 114 symptomatic patients and 88 healthy volunteers. Cervical spinal cord was segmented automatically through a trained convolutional neuronal network with subsequent T2-SI registration slice-by-slice. Received T2-SI curves were subdivided for each cervical level from C2 to C7. Additionally, all levels were subjectively classified concerning a present T2 hyperintensity. For T2-positive levels, corresponding T2-SI curves were compared to curves of age-matched volunteers at the identical level. RESULTS: Forty-nine patients showed subjective T2 hyperintensities at any level. The corresponding T2-SI curves showed higher signal variabilities reflected by standard deviation (18.51 vs. 7.47 a.u.; p < 0.001) and range (56.09 vs. 24.34 a.u.; p < 0.001) compared to matched controls. Percentage of the range from the mean absolute T2-SI per cervical level, introduced as "T2 myelopathy index" (T2-MI), was correspondingly significantly higher in T2-positive segments (23.99% vs. 10.85%; p < 0.001). ROC analysis indicated excellent differentiation for all three parameters (AUC 0.865-0.920). CONCLUSION: This fully automated T2-SI quantification of the spinal cord revealed significantly increased signal variability for DCM patients compared to healthy volunteers. This innovative procedure and the applied parameters showed sufficient diagnostic accuracy, potentially diagnosing radiological DCM more objective to optimize treatment recommendation. TRIAL REGISTRATION: DRKS00012962 (17.01.2018) and DRKS00017351 (28.05.2019).


Asunto(s)
Compresión de la Médula Espinal , Enfermedades de la Médula Espinal , Humanos , Estudios Prospectivos , Vértebras Cervicales/diagnóstico por imagen , Enfermedades de la Médula Espinal/diagnóstico por imagen , Médula Espinal/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos
5.
Eur Radiol ; 33(8): 5578-5586, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36890304

RESUMEN

OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS: In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CTstd) and (2) 130-keV monoenergetic images (PC-CT130 keV). Prior EID-CT was available for 17 patients; for the remaining 15, an age-, sex-, and body mass index-matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CTstd and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CTstd and PC-CT130 keV images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CTstd and PC-CT130 keV. Finally, the radiation dose (CTDIvol) was evaluated. RESULTS: Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT130 keV revealed superior ratings vs. PC-CTstd for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDIvol: 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS: PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS: • Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. • In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.


Asunto(s)
Enfermedades de la Columna Vertebral , Tomografía Computarizada por Rayos X , Humanos , Fantasmas de Imagen , Fotones , Estudios Prospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Columna Vertebral/diagnóstico por imagen , Enfermedades de la Columna Vertebral/diagnóstico por imagen
6.
Global Spine J ; 13(6): 1541-1549, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34530629

RESUMEN

STUDY DESIGN: Prospective cohort study. OBJECTIVES: The purpose of this prospective study was to evaluate a protocol for radiation-sparing kyphoplasty by assessing dosemetrically recorded radiation exposures to both patient and surgeon. METHODS: This prospective clinical study examines the radiation exposure to patient and surgeon during single-level kyphoplasty in 32 thoracolumbar osteoporotic vertebral body fractures (12 OF 2, 9 OF 3, 11 OF 4 types) using a radiation aware surgical protocol between May 2017 and November 2019. The radiation exposure was measured at different locations using film, eye lens and ring dosemeters. Dose values are reported under consideration of lower detection limits of each dosemeter type. RESULTS: A high proportion of dosemeter readings was below the lower detection limits, especially for the surgeon (>90%). Radiation exposure to the surgeon was highest at the unprotected thyroid gland (0.053 ± 0.047 mSv), however only slightly above the lower detection limit of dosemeters (0.044 mSv). Radiation exposure to the patient was highest at the chest (0.349 ± 0.414 mSv) and the gonad (0.186 ± 0.262 mSv). Fluoroscopy time, dose area product and number of fluoroscopic images were 46.0 ± 17.9 sec, 124 ± 109 cGy×cm2, and 35 ± 13 per kyphoplasty, respectively. Back pain significantly improved from 6.8 ± 1.6 to 2.5 ± 1.7 on the numeric rating scale on the first postoperative day (P < 0.0001). CONCLUSIONS: The implementation of a strict intraoperative radiation protection protocol allows for safely performed kyphoplasty with ultra-low radiation exposure for the patient and surgeon without exceeding the annual occupational dose limits. TRIAL REGISTRATION: The study was registered in the German Clinical Trials Register (DRKS00011908, registration date 16/05/2017).

7.
J Neurosurg Spine ; 38(1): 147-152, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36087332

RESUMEN

OBJECTIVE: Spinal CSF leaks cause spontaneous intracranial hypotension (SIH). Surgical closure of spinal CSF leaks is the treatment of choice for persisting leaks. Surgical approaches vary, and there are no studies in which minimally invasive techniques were used. In this study, the authors aimed to detail the safety and feasibility of minimally invasive microsurgical sealing of spinal CSF leaks using nonexpandable tubular retractors. METHODS: Consecutive patients with SIH and a confirmed spinal CSF leak treated at a single institution between April 2019 and December 2020 were included in the study. Surgery was performed via a dorsal 2.5-cm skin incision using nonexpandable tubular retractors and a tailored interlaminar fenestration and, if needed, a transdural approach. The primary outcome was successful sealing of the dura, and the secondary outcome was the occurrence of complications. RESULTS: Fifty-eight patients, 65.5% of whom were female (median age 46 years [IQR 36-55 years]), with 38 ventral leaks, 17 lateral leaks, and 2 CSF venous fistulas were included. In 56 (96.6%) patients, the leak could be closed, and in 2 (3.4%) patients the leak was missed because of misinterpretation of the imaging studies. One of these patients underwent successful reoperation, and the other patient decided to undergo surgery at another institution. Two other patients had to undergo reoperation because of insufficient closure and a persisting leak. The rate of permanent neurological deficit was 1.7%, the revision rate for a persisting or recurring leak was 3.4%, and the overall revision rate was 10.3%. The rate of successful sealing during the primary closure attempt was 96.6% and 3.4% patients needed a secondary attempt. Clinical short-term outcome at discharge was unchanged in 14 patients and improved in 25 patients, and 19 patients had signs of rebound intracranial hypertension. CONCLUSIONS: Minimally invasive surgery with tubular retractors and a tailored interlaminar fenestration and, if needed, a transdural approach is safe and effective for the treatment of spinal CSF leaks. The authors suggest performing a minimally invasive closure of spinal CSF leaks in specialized centers.


Asunto(s)
Hipotensión Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Hipotensión Intracraneal/diagnóstico por imagen , Hipotensión Intracraneal/cirugía , Recurrencia Local de Neoplasia/cirugía , Pérdida de Líquido Cefalorraquídeo/diagnóstico por imagen , Pérdida de Líquido Cefalorraquídeo/cirugía , Pérdida de Líquido Cefalorraquídeo/complicaciones , Procedimientos Neuroquirúrgicos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos
8.
Spine J ; 22(9): 1576-1578, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35351665

RESUMEN

Intraoperative CT imaging is becoming increasingly used, but often little attention is paid to the underlying radiation exposure to the patient. This work showed that the dosimetrically assessed radiation exposure for cervical and lumbar 3D scans with an intraoperative CT is considerably higher than with a 3D C-arm. Therefore, proper selection of the intraoperative 3D imaging system is essential, and further technological developments and dose-saving protocols are warranted to further reduce patient radiation exposure.


Asunto(s)
Exposición a la Radiación , Cirugía Asistida por Computador , Humanos , Imagenología Tridimensional/métodos , Región Lumbosacra , Procedimientos Neuroquirúrgicos , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Cirugía Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/efectos adversos , Tomografía Computarizada por Rayos X/métodos
9.
BMC Musculoskelet Disord ; 23(1): 104, 2022 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-35101020

RESUMEN

BACKGROUND: The common manual measurement technique of spinal sagittal alignment on X-rays is susceptible to rater-dependent variability, which has not been adequately considered in previous publications. This study investigates the effect of those variations in the characterization of patients receiving lumbar spondylodesis. METHODS: General alignment parameters on pre- and postoperative X-rays were evaluated by four raters in 43 prospectively sampled patients undergoing monolevel spondylodesis. The Intra-class Correlation Coefficient (ICC) for each rater pair and all raters together was calculated for inter-rater reliability. For the operation-induced change of the sagittal alignment in every patient the Wilcoxon test was applied to compare for each rater separately. RESULTS: The ICCs were "good" (>0.75) to "excellent" (>0.9) for all raters together and for 45 of the 48 single rater pairs (93.75%). All revealed a significant increase of the addressed segmental lordosis and disc height and no significant change for spinopelvic parameters and sagittal vertical axis from pre- to postoperative. The lumbar lordosis showed a significant increase through the operation of +2.5° (p = 0.014) and +3.7° (p = 0.015) in two raters and no difference for the other ones (+2.1°, p = 0.171; -2.2°, p = 0.522). CONCLUSIONS: The pre- to postoperative change of lumbar lordosis revealed different significance levels for different raters, although the ICCs were formally good. Accordingly, the evaluation by only one rater would lead to different conclusions. Due to this susceptibility of alignment measurements to rater-dependent variability, the exact evaluation process should be described in every publication and the consistency of significant results be validated through multiple raters. TRIALS REGISTRATION: The trial was approved by the local ethics committee and listed at the national clinical trials register ( DRKS00004514 , date of registration: 08/11/2012).


Asunto(s)
Lordosis , Fusión Vertebral , Humanos , Lordosis/diagnóstico por imagen , Lordosis/cirugía , Variaciones Dependientes del Observador , Radiografía , Reproducibilidad de los Resultados
10.
J Neurosurg Spine ; 36(1): 160-163, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-34507298

RESUMEN

OBJECTIVE: A major challenge of a minimally invasive spinal approach (MIS) is maintaining freedom of maneuverability through small operative corridors. Unfortunately, during tubular resection of intradural pathologies, the durotomy and its accompanying tenting sutures offer a smaller operating window than the maximum surface of the tube's base. The objective of this study was to evaluate if a novel double tubular technique could expand the surgical visual field during MIS resection of intradural pathologies. METHODS: A total of 25 MIS resections of intradural extramedullary pathologies were included. A posterior tubular interlaminar fenestration was performed in all surgeries. A durotomy covering the whole diameter of the tubular base was the standard in all cases. After placement of two tenting sutures on each side of the durotomy and application of tension, the resulting surface of the achieved dura fenestration was measured after optical analysis of the intraoperative video. In the next step, a second tube, 2 mm thinner than and the same length as the first, was inserted telescopically into the first tube, resulting an angulated fulcrum effect on the tenting sutures. RESULTS: Optical surface analysis of the dura fenestration before and after the second tubular insertion verified a significant widening of the visual field of 43.1% (mean 18.84 mm2, 95% CI 16.8-20.8, p value < 0.001). There were no ruptured tenting sutures through the increased tension. Postoperative MRIs verified complete resection of the pathologies. CONCLUSIONS: Inserting a second tube telescopically during posterior minimally invasive tubular spinal intradural surgery leads to an angulated fulcrum effect on the dura tenting sutures which consequently increases the surface of the dura fenestration and induces a meaningful widening of the visual field.


Asunto(s)
Duramadre/cirugía , Neoplasias Meníngeas/cirugía , Meningioma/cirugía , Neurilemoma/cirugía , Procedimientos Neuroquirúrgicos/métodos , Neoplasias de la Médula Espinal/cirugía , Estudios de Cohortes , Duramadre/patología , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Campos Visuales
11.
Spinal Cord ; 60(7): 655-663, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34966172

RESUMEN

DESIGN: Prospective diagnostic study. OBJECTIVES: Primary imaging-based diagnosis of spinal cord tumor-suspected lesions is often challenging. The identification of the definite entity is crucial for dedicated treatment and therefore reduction of morbidity. The aim of this trial was to investigate specific quantitative signal patterns to differentiate unclear intramedullary tumor-suspected lesions based on diffusion tensor imaging (DTI). SETTING: Medical Center - University of Freiburg, Germany. METHODS: Forty patients with an unclear tumor-suspected lesion of the spinal cord prospectively underwent DTI. Primary diagnosis was determined by histological or clinical work-up or remained indeterminate with follow-up. DTI metrics (FA/ADC) were evaluated at the central lesion area, lesion margin, edema, and normal spinal cord and compared between different diagnostic groups (ependymomas, other spinal cord tumors, inflammations). RESULTS: Mean DTI metrics for all spinal cord tumors (n = 18) showed significantly reduced FA and increased ADC values compared to inflammatory lesions (n = 8) at the lesion margin (p < 0.001, p = 0.001) and reduced FA at the central lesion area (p < 0.001). There were no significant differences comparing the neoplastic subgroups of ependymomas (n = 10) and other spinal cord tumors (n = 8), but remaining differences for both compared to the inflammation subgroup. We found significant higher ADC (p = 0.040) and a trend to decreased FA (p = 0.081) for ependymomas compared to inflammations at the edema. CONCLUSION: Even if distinct differentiation of ependymomas from other spinal cord neoplasms was not possible based on quantitative DTI metrics, FA and ADC were feasible to separate inflammatory lesions. This may avoid unnecessary surgery in patients with unclear intramedullary tumor-suspected lesions.


Asunto(s)
Ependimoma , Enfermedades de la Médula Espinal , Traumatismos de la Médula Espinal , Neoplasias de la Médula Espinal , Imagen de Difusión Tensora/métodos , Ependimoma/diagnóstico por imagen , Ependimoma/patología , Humanos , Inflamación/diagnóstico por imagen , Inflamación/patología , Estudios Prospectivos , Médula Espinal/patología , Traumatismos de la Médula Espinal/patología , Neoplasias de la Médula Espinal/diagnóstico por imagen , Neoplasias de la Médula Espinal/patología
12.
J Clin Neurosci ; 94: 135-139, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34863428

RESUMEN

For patients with multilevel degenerative cervical myelopathy (DCM), laminectomy and fusion is an established technique. A concomitant effect of multilevel fusion is a restriction of cervical spine mobility. This retrospective study on DCM-patients with at least 4 laminectomy and fusion levels, compares data between objective and subjective restriction of the postoperative cervical spine mobility. The patient-reported restriction of cervical spine mobility was acquired by a five-step score. Measurements of cervical range of motion were performed using the CROM device and were correlated with the subjective scores. Fusion was performed over 6 levels in most of the 36 patients. For the subjective cervical spine mobility, 52.8% reported none to medium, 38.9% severe and 8.3% complete restriction. Mean objective cervical range of motion was 45.0° for flexion-extension, 26.3° for total lateral flexion and 51.4° for total rotation and therefore evidently reduced compared to non-operated patient cohorts in literature. There was a significant medium, negative correlation between the objective measurements and the patient-reported general restriction of cervical spine mobility, and with the physical component summary of SF-8. The significant objective reduction of cervical range of motion after laminectomy and multilevel fusion correlates with the patient-reported assessment for general restriction.


Asunto(s)
Laminectomía , Enfermedades de la Médula Espinal , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Humanos , Rango del Movimiento Articular , Estudios Retrospectivos , Enfermedades de la Médula Espinal/cirugía
13.
J Clin Med ; 10(17)2021 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-34501236

RESUMEN

In degenerative cervical myelopathy (DCM), focally increased spinal cord motion has been observed for C5/C6, but whether stenoses at other cervical segments lead to similar pathodynamics and how severity of stenosis, age, and gender affect them is still unclear. We report a prospective matched-pair controlled trial on 65 DCM patients. A high-resolution 3D T2 sampling perfection with application-optimized contrasts using different flip angle evolution (SPACE) and a phase-contrast magnetic resonance imaging (MRI) sequence were performed and automatically segmented. Anatomical and spinal cord motion data were assessed per segment from C2/C3 to C7/T1. Spinal cord motion was focally increased at a level of stenosis among patients with stenosis at C4/C5 (n = 14), C5/C6 (n = 33), and C6/C7 (n = 10) (p < 0.033). Patients with stenosis at C2/C3 (n = 2) and C3/C4 (n = 6) presented a similar pattern, not reaching significance. Gender was a significant predictor of higher spinal cord dynamics among men with stenosis at C5/C6 (p = 0.048) and C6/C7 (p = 0.033). Age and severity of stenosis did not relate to spinal cord motion. Thus, the data demonstrates focally increased spinal cord motion depending on the specific level of stenosis. Gender-related effects lead to dynamic alterations among men with stenosis at C5/C6 and C6/C7. The missing relation of motion to severity of stenosis underlines a possible additive diagnostic value of spinal cord motion analysis in DCM.

14.
Clin Biomech (Bristol, Avon) ; 90: 105484, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34547606

RESUMEN

BACKGROUND: Laminectomy and multilevel fusion in patients with degenerative cervical myelopathy lead to severe restriction in cervical spine mobility. Since fusions from C2 to the thoracic spine result in a permanently stiff subaxial cervical spine, it seems obvious to restore physiological cervical lordosis, especially with regard to sagittal balance. However, there are reports that a fusion in a more lordotic position leads to a reduction of rotational cervical range of motion in the still mobile segments C0-C2. This study investigates the relationship between postoperative cervical lordosis and the objective rotational range of motion and subjective restriction. METHODS: In this single-center, retrospective cohort study, patients with degenerative cervical myelopathy operated via laminectomy and fusion from C2 to the thoracic spine were included. X-ray imaging was evaluated for common lordosis parameters. The patient-reported rotational restriction of cervical spine mobility was acquired by a five-step score. Objective rotational range of motion was measured. The radiological parameters for cervical lordosis (C2-C7 lordotic angle, C2-C7 Cobb angle) were correlated with the measurements and the patient-reported subjective scores. FINDINGS: We found a significant, medium negative correlation between the measurements for rotation and the C2-C7 lordotic angle and a significant, large negative correlation to the C2-C7 Cobb angle. For subjective restriction, no or only small correlation was observed. INTERPRETATION: We found significant negative correlations between radiological cervical lordosis and objective measurements for rotation. These results indicate that for this particular patient population, a stronger postoperative cervical lordosis does not seem favorable under the aspect of rotational range of motion.


Asunto(s)
Lordosis , Enfermedades de la Médula Espinal , Fusión Vertebral , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Humanos , Lordosis/diagnóstico por imagen , Lordosis/cirugía , Rango del Movimiento Articular , Estudios Retrospectivos
15.
Spine (Phila Pa 1976) ; 46(18): 1241-1248, 2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34435986

RESUMEN

STUDY DESIGN: Prospective, observational study. OBJECTIVE: The aim of this study was to collect objective and especially subjective data on changes in cervical spine mobility after single-level anterior cervical decompression and fusion (ACDF) and to investigate the impact on quality of life and activities of daily living (ADLs). SUMMARY OF BACKGROUND DATA: Although there are several studies dealing with the objective change in mobility after single-level ACDF, there are few data on how spondylodesis of a motion segment affects subjective restriction of cervical spine mobility. METHODS: Patients undergoing first-time, single-level ACDF for a symptomatic spondylotic process were eligible. Data were collected before surgery, at 3-month, and 1-year follow-up. Patients were assessed via clinical scores (pain intensity, Short-Form 8 [SF-8], among others) and asked for impairment in ADLs due to restriction of cervical spine mobility. The subjective restriction was acquired by a five-step patient-reported score. The range of motion was measured by the CROM device. RESULTS: Data of 97 patients could be evaluated. For pain scores and SF-8 there were significant improvements 3 months and 1 year after surgery (P < 0.001). The impairment for most ADLs improved 3 months after surgery and further after 1 year. The subjective restriction showed a significant improvement in general and for all single directions 1 year after surgery. In the objective measurements, a significantly higher total rotation could be found 1 year after surgery compared to preoperatively (101.6° ± 21.2 vs. 93.9° ± 23.4; P = 0.002). There were no significant differences in total flexion-extension and lateral flexion. Increasing age was a significant predictor for objective and subjective restriction. CONCLUSION: The concern of many patients of being severely restricted in their cervical spine mobility after single-level ACDF can be denied. Objectively, the rotation even showed a significant improvement. Regarding the subjective restriction, which is more important for the patients, we found a significant improvement in general and for all directions of movement after surgery.Level of Evidence: 3.


Asunto(s)
Actividades Cotidianas , Fusión Vertebral , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Descompresión , Discectomía , Humanos , Estudios Prospectivos , Calidad de Vida , Rango del Movimiento Articular , Resultado del Tratamiento
16.
Spine J ; 21(8): 1243-1245, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33865983

RESUMEN

The annual limit value for the eye lens dose for occupationally exposed personnel has recently been considerably reduced from 150mSv to 20mSv. We have therefore re-evaluated the effectiveness of radiation protection measures (lead glass goggles, mobile radiation shielding wall and distance to the radiation source) in an experimental setting to provide spinal surgeons with clearly understandable radiation dose data for their daily work.


Asunto(s)
Cristalino , Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Cirujanos , Humanos , Exposición Profesional/efectos adversos , Dosis de Radiación , Exposición a la Radiación/análisis
17.
Acta Ophthalmol ; 99(8): e1492-e1500, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33720516

RESUMEN

BACKGROUND/AIMS: Retinal haemangioblastomas (RH) remain a major cause of visual impairment in patients with von Hippel-Lindau (VHL) disease. Identification of genotype-phenotype correlation is an important prerequisite for better management, treatment and prognosis. METHODS: Retrospective, single-centre cohort study of 200 VHL patients. Genetic data and date of onset of RH, central nervous system haemangioblastomas (CNSH), pheochromocytoma/paraganglioma (PPGL), clear cell renal cell carcinoma (ccRCC) and pancreatic neuroendocrine neoplasm (PNEN) were collected. The number and locations of RH were recorded. RESULTS: The first clinical finding occurred at an age of 26 ± 14 years (y) [mean ± SD]. In 91 ± 3% (95% CI 88-94) of the patients, at least one RH occur until the age of 60y. A total of 42 different rare VHL gene variants in 166 patients were detected. A higher age-related incidence of RH, CNSH, ccRCC and PNEN was detected in patients with a truncating variant (TV) compared to patients with a single amino-acid substitution/deletion (AASD) (all p < 0.01), while it is reverse for PPGL (p < 0.01). Patients with a TV showed 0.10 ± 0.15 RH per y during their lifetime compared to 0.05 ± 0.07 in patients with AASD (p < 0.02). The median enucleation/phthisis-free survival time in patients with a TV was 56y (95% CI 50-62) compared to 78y (95% CI 75-81) in patients with AASD (p < 0.02). CONCLUSION: Compared to patients with AASD, patients with a TV develop RH, CNSH, ccRCC and PNEN earlier. They experience a higher number of RH and bear a higher risk of enucleation/phthisis. Thus, patients with a TV might be considered for a more intensive ophthalmological monitoring.


Asunto(s)
Estudios de Asociación Genética/métodos , Predisposición Genética a la Enfermedad , Hemangioblastoma/etiología , Retina/diagnóstico por imagen , Neoplasias de la Retina/etiología , Enfermedad de von Hippel-Lindau/genética , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Análisis Mutacional de ADN , Femenino , Angiografía con Fluoresceína/métodos , Estudios de Seguimiento , Fondo de Ojo , Alemania/epidemiología , Hemangioblastoma/diagnóstico , Hemangioblastoma/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Morbilidad/tendencias , Mutación , Neoplasias de la Retina/diagnóstico , Neoplasias de la Retina/epidemiología , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Proteína Supresora de Tumores del Síndrome de Von Hippel-Lindau/genética , Proteína Supresora de Tumores del Síndrome de Von Hippel-Lindau/metabolismo , Adulto Joven , Enfermedad de von Hippel-Lindau/complicaciones , Enfermedad de von Hippel-Lindau/epidemiología
18.
Neuroimage Clin ; 30: 102580, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33578322

RESUMEN

BACKGROUND: Focally increased spinal cord motion at the level of cervical spinal stenosis has been revealed by phase-contrast MRI (PC-MRI). OBJECTIVE: To investigate spinal cord motion among patients suffering of degenerative cervical myelopathy (DCM) across the entire cervical spine applying automated segmentation and standardized PC-MRI post-processing protocols. METHODS: Prospective, matched-pair controlled trial on 29 patients with stenosis at C5/C6. MRI-protocol covering all cervical segments: 3D T2-SPACE, prospectively ECG-triggered sagittal PC-MRI. Segmentation by trained 3D hierarchical deep convolutional neural network and data processing were conducted via in-house software pipeline. Parameters per segment: maximum velocity, peak-to-peak (PTP)-amplitude, total displacement, PTP-amplitudeHB (PTP-amplitude per duration of heartbeat), and, for characterization of intraindividual alterations, the PTP-amplitude index between the cervical segments C3/C4-C7/T1 and C2/C3. RESULTS: Spinal cord motion was increased at C4/C5, C5/C6 and C6/C7 among patients (all parameters, p < 0.001-0.025). The PTP-amplitude index revealed an increase from C3/C4 to C4/C5 (p = 0.002), C4/C5 to C5/C6 (p = 0.037) and a decrease from C5/C6 to C6/C7 and C6/C7 to C7/T1 (p < 0.001, each). This implied an up-building stretch on spinal cord tissue cranial and a mechanical compression caudal of the stenotic level. Furthermore, significant far range effects across the entire cervical spinal cord were observed (e.g. PTP-amplitude C2/C3 vs. C6/C7, p = 0.026) in contrast to controls (p = 1.00). CONCLUSION: This study revealed the nature and extends of mechanical stress on the entire cervical spinal cord tissue due to focal stenosis. These pathophysiological alterations of spinal cord motion can be expected to be clinically relevant.


Asunto(s)
Médula Cervical , Estenosis Espinal , Médula Cervical/diagnóstico por imagen , Vértebras Cervicales/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Análisis por Apareamiento , Estudios Prospectivos , Médula Espinal , Estenosis Espinal/diagnóstico por imagen
19.
World Neurosurg ; 148: e556-e564, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33476777

RESUMEN

OBJECTIVE: For patients with multilevel degenerative cervical myelopathy, laminectomy and fusion are widely accepted techniques for ameliorating the disorder. However, the idea of whether one should bridge the cervicothoracic junction to prevent instrument failure or adjacent segment disease has been a subject of controversial discussion. In the present study, we compared the incidence of these complications and the revision rates in multilevel fusions extending to C7 or T1-T3. METHODS: In the present single-center, retrospective cohort study, patients with multilevel degenerative cervical myelopathy treated with laminectomy and fusion to C7 or T1-T3 from 2004 to 2016 were included for evaluation. The primary outcome measure was radiologically proven complications at the most caudal level or the adjacent spinal fusion level. RESULTS: Laminectomy and multilevel fusion were performed in 84 patients. After applying the exclusion criteria, 20 patients with fusion to C7 (treated from 2004 to 2012; follow-up, 124.6 ± 10.6 months) and 38 patients with fusion to T1-T3 (treated from 2008 to 2016; follow-up, 58.2 ± 15.7 months) were evaluated. The incidence of complications at the most caudal or adjacent level of fusion was twice as high (P = 0.087; NS) in the C7 group (11 of 20; 55.0%) compared with the T1-T3 group (11 of 38; 28.9%). In the C7 group, 9 of the 20 patients (45.0%) had required revision surgery compared with 2 of 38 patients (5.3%) in the T1-T3 group (P = 0.001). CONCLUSIONS: We found that fewer revisions were necessary if the fusion had extended to the thoracic spine. Thus, we recommend bridging the cervicothoracic junction when fusion starts at C0-C3.


Asunto(s)
Vértebras Cervicales/cirugía , Degeneración del Disco Intervertebral/cirugía , Procedimientos Neuroquirúrgicos/métodos , Fusión Vertebral/métodos , Vértebras Torácicas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Vértebras Cervicales/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Degeneración del Disco Intervertebral/diagnóstico por imagen , Laminectomía , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Vértebras Torácicas/diagnóstico por imagen , Resultado del Tratamiento
20.
J Neurol Surg A Cent Eur Neurosurg ; 82(3): 278-284, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33477189

RESUMEN

BACKGROUND AND STUDY OBJECTIVE: One risk of established decompression techniques for lumbar spinal stenosis is the resection of facet joints, especially if they are steeply configured, promoting destabilization. Minimally invasive bilateral crossover decompression aims to preserve the facet joints and thus stability of the spine. The purpose of this study is to demonstrate the feasibility and early results of this technique. METHODS: This retrospective case series includes 10 consecutive patients with lumbar stenosis and steep-angle (<35 degrees) facet joints who were treated with minimally invasive bilateral crossover decompression. Eleven segments were decompressed, most commonly L3/L4 (63.6%), followed by L1/L2 and L2/L3 (18.2% each). The effectiveness of surgical decompression was assessed by self-reporting questionnaires. RESULTS: After a follow-up of 10.5 months, the Symptom Severity Scale and Physical Function Scale of the Swiss Spinal Stenosis Questionnaire improved by 0.9 (p < 0.05) and 0.7 points, respectively. The mean Oswestry Disability Index improved from 53.9 to 34.6 (p < 0.05). Local and radiating pain under strain showed statistically significant improvement on the Visual Analog Scale (8.9 vs. 5.0 and 8.4 vs. 4.6, respectively). Maximum walking distance increased from 190 to 1,029 m. Apart from one patient requiring surgical decompression of an adjacent segment, there were no reoperations, neurological deteriorations, or other complications. CONCLUSION: The results of this study indicate that minimally invasive bilateral crossover decompression is a promising technique for the treatment of spinal canal stenosis. With its design to spare facet joints, it can potentially reduce the risk of spinal instability, especially in patients with steep facet joints.


Asunto(s)
Descompresión Quirúrgica/métodos , Vértebras Lumbares/cirugía , Región Lumbosacra/cirugía , Estenosis Espinal/cirugía , Anciano , Humanos , Inestabilidad de la Articulación/cirugía , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Estudios Retrospectivos , Encuestas y Cuestionarios , Resultado del Tratamiento , Articulación Cigapofisaria/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...